PFA Tubes Working Bursting Pressure Specifications (+23°C)
Code |
Exterior Diameter |
Interior Diameter |
Wall Thickness |
Working pressure |
Burst pressure |
Colours |
PFA4060 |
4 |
6 |
1 |
21 |
108 |
 |
PFA6080 |
6 |
8 |
1 |
15 |
78 |
 |
PFA8010 |
8 |
10 |
1 |
12 |
61 |
 |
PFA1012 |
10 |
12 |
1 |
10 |
50 |
 |
Indvative maximum working pressure to be calculated using a safety factor of 5
Temperature affects pressure resistance:
T (°C) 20 50 100 150 200 250
P (% ) 100 85 60 48 35 20
Code |
Exterior Diameter |
Interior Diameter |
Wall Thickness |
Working pressure |
Burst pressure |
Colours |
FEP2040 |
2 |
4 |
1 |
- |
- |
 |
FEP4060 |
4 |
6 |
1 |
19 |
96 |
 |
FEP6080 |
6 |
8 |
1 |
14 |
70 |
 |
FEP8010 |
8 |
10 |
1 |
11 |
55 |
 |
FEB1012 |
10 |
12 |
1 |
9 |
45 |
 |
Indvative maximum working pressure to be calculated using a safety factor of 5
Temperature affects pressure resistance:
T (°C) 20 50 100 150
P (% ) 100 80 45 20